Door Compatibility Installation Lockin Smart Locks
23 сент. 2026 г.
official Lockin

Retrofit Smart Lock or Full Replacement: Which Lockin Installation Path Applies?

Two women examine brass deadbolt parts in a box beside an open wooden door fitted with a smart lock.

Treat the Veno installation described here as replacement of the compatible deadbolt hardware, not an interior adapter that turns every existing lock. Reusing suitable door preparation can avoid a new bore while still requiring the supplied lock components to replace the old ones. Identify the existing mechanism and compare it with the exact candidate’s guide before ordering. If the door uses a different lock form or an unclear preparation, preserve the working hardware and obtain a model-specific fit answer before making alterations.

Retrofit and replacement do not mean the same thing

In smart-lock shopping, “retrofit” can mean two different installation paths:

  • Interior retrofit: the outside cylinder and deadbolt stay in place while a motorized interior unit turns the existing thumbturn.
  • Deadbolt replacement: the existing deadbolt hardware comes out and the new smart lock uses the door’s existing preparation.

Read no-drilling language as a statement about compatible existing preparation, not about retaining the existing lock body. The installation paths above replace different components, and the Veno guide describes installing the supplied assemblies and associated hardware. Check what the candidate requires you to remove and fit before selecting it. This distinction matters when the exterior cylinder, building access arrangement or restoration requirement must be preserved, because an interior-only expectation would lead to the wrong purchase even if the hole size looked suitable.

Which Lockin installation path applies?

Use the hardware table as an initial fit screen, then verify every relevant condition for the exact model. Identify whether the deadbolt is separate from the handle and record an unfamiliar mechanism with photographs of the door faces, edge and strike. Keep the existing lock in place while clarifying the preparation. Passing an isolated measurement does not establish the full installation, and a similar appearance should not substitute for the model-specific answer needed before replacing a working entrance.

What you have now Likely path What to do
Compatible single-cylinder deadbolt on a standard entry door Full Lockin deadbolt replacement using existing preparation Measure the door and compare it with the exact model guide.
Standard deadbolt, but dimensions or faceplate are unknown Replacement pending a fit check Keep the existing lock installed; measure and photograph it first.
Mortise, multipoint, interconnected, or narrow-stile lock Not a standard Veno replacement path Do not drill or file; ask Lockin or a qualified door professional about the exact model.
Round latch faceplate or nonstandard holes Do not assume compatibility Compare the exact model’s preparation requirements before purchase.
Storm door or another door that blocks a video lock’s camera Model-specific stop condition The Veno Pro and Veno Plus FAQ lists storm doors as incompatible. Clear camera sightlines alone do not override that restriction; compare any other outer-door arrangement with the exact model’s guide before purchase.

The measurements that decide whether replacement can use existing holes

Check Published requirement Why it matters
Lock type Standard American deadbolt; single cylinder The new assemblies must connect to the deadbolt preparation rather than a mortise case.
Door thickness 35–55 mm (1⅜–2¹¹⁄₆₄ in) The interior and exterior assemblies need the correct clamping depth.
Crossbore 54 mm (2⅛ in) This is the large hole through the door face.
Backset 60 or 70 mm (2⅜ or 2¾ in) This is the distance from the door edge to the crossbore center.
Door-edge hole 25.4 mm (1 in) The latch and bolt must sit correctly in the edge preparation.
Latch-faceplate cutout Rectangular Lockin lists round faceplate cutouts as incompatible for the Veno guidance.
Latch-box depth At least 25.4 mm (1 in) The bolt needs room to extend and retract without binding.

Measure the actual door slab and preparation with the door accessible, including the strike, surrounding handle and any outer door. Compare those observations with the requirements above and the selected model’s guide rather than measuring decorative trim or relying on an image. Record existing movement and any rubbing before changing hardware. This gives a fit enquiry concrete evidence and helps distinguish a new installation problem from pressure or misalignment already present at the entrance.

What a full Lockin replacement involves

Follow the exact-model assembly sequence after permission and fit are established, retaining the original hardware until the replacement works. The procedure involves the supplied latch and assemblies, cable routing and mounting, followed by mechanical and configured-entry checks under the guide’s permitted conditions. This article identifies the installation path rather than replacing that sequence. Stop at resistance or an unclear connection instead of enlarging holes or forcing components to make a general diagram fit the door.

When should you stop instead of choosing a retrofit?

Pause the purchase or alteration when the mechanism, preparation, clearance or permission remains outside the confirmed installation path. Send the selected model, measured conditions and complete doorway photographs to support or an appropriate door professional. Do not use an easy-install claim as evidence that a binding bolt, blocked camera or different lock body can be accommodated. Preserve the existing entrance until the proposed replacement has a specific answer for the unresolved condition and an approved way to complete the work.

Updated October 15, 2026