Buyer Guide Compatibility Lockin Smart Locks
2026年9月30日
official Lockin

What Should You Confirm Before Ordering a Lockin Smart Lock for a Condo?

Confirm condo approval, exact door fit, camera and solar rules, building access, and backup entry before ordering a Lockin smart lock.
A woman photographs door hardware while a man holds an uninstalled smart lock in a condo hallway.

Before ordering a Lockin smart lock for a condo, confirm four things in writing: your building allows the hardware change, the exact model fits the unit’s door preparation, the building’s access and privacy rules still work, and your power and backup-entry plan is practical. Condo ownership does not automatically mean you can change every part of an entry door.

The safest order is permission → door fit → building constraints → model and ownership plan. If any step is uncertain, pause the order and send Lockin the model name, measurements, and door photos before drilling or removing hardware.

1. Confirm who controls the door and what approval is required

Request approval for the named hardware change rather than asking only whether smart locks are allowed. Include the exterior and interior assemblies, strike and any proposed alteration to the door preparation, and identify whether the opening is subject to a building key system or other managed requirement. Keep the responsible manager’s written answer with the door record. This gives the installer a defined scope and prevents a general permission to use a device from being mistaken for permission to change every part of the entrance.

Have the responsible building team resolve controlled-opening requirements before any physical alteration. A shared corridor, labeled door or managed access arrangement may need review beyond ordinary product fit, and this article cannot establish that approval. Keep drilling, bore enlargement and strike replacement out of the plan until the relevant requirement is resolved. The purpose of the purchase check is to identify the decision owner and the exact proposed work, so a consumer measurement is not used as a substitute for building authorization.

2. Identify the existing lock before choosing a Lockin model

Identify the existing lock form before comparing the candidate’s features. Use the hardware categories below to distinguish an ordinary deadbolt preparation from a different or managed opening, and photograph the exterior, interior, door edge, strike and neighboring hardware if the type is unclear. Send those views with the exact candidate model when requesting assistance. Calling the door standard does not establish its preparation, so keep the product choice provisional until the actual opening has been identified.

Existing condition Ordering decision
Standard bored, single-cylinder deadbolt Continue to the measurement checks.
Mortise, multipoint, interconnected, narrow-stile, panic, or institutional hardware Stop and request model-specific or professional review.
Building card, fob, wired, or managed electronic access Confirm that the building’s required access method will remain available.
Fire-rated, labeled, shared-egress, or otherwise controlled opening Obtain approval from the responsible authority before touching the hardware.
Storm door or screen door near the entry Veno Pro and Veno Plus documentation excludes storm doors; extra clearance does not establish compatibility. For another model or a separate screen-door arrangement, check its own installation guidance before ordering.
French door or unusual two-door arrangement Do not assume a Veno deadbolt is compatible; verify the exact model.

3. Measure the door for the exact model

Record the actual door measurements, units, strike arrangement and surrounding clearance against the selected model’s guide. Use the table below to collect the details; do not alter the door to resolve an uncertain fit.

Check What to record Why it matters
Door material and thickness Material; 35–55 mm (1⅜–2¹¹⁄₆₄ in) where the model specifies it The body and mounting hardware must span the door correctly.
Crossbore Diameter of the large hole: 38 mm (1½ in) or 54 mm (2⅛ in), as supported by the model The exterior and interior assemblies must align.
Backset Door edge to the center of the crossbore: 60 or 70 mm (2⅜ or 2¾ in) The latch must line up with the bore and strike.
Edge bore and latch 25.4 mm (1 in) edge hole; rectangular or round faceplate The latch preparation must match the exact guide.
Strike and pocket Depth, alignment, and clearance in the frame A motor cannot reliably correct a tight or misaligned door.
Nearby clearance Handle, trim, glass, door stop, wall, and second-door spacing The lock must open, close, and remain serviceable without collision.

The current Veno product guidance is model-specific. For example, Veno Go and the two Veno Solar models show 38 or 54 mm crossbore options, while Veno and the current Veno Pro and Veno Plus product pages use 54 mm. Lockin’s current fit guide also notes a documentation boundary for Pro and Plus: some linked guides illustrate both bore sizes while the product pages specify 54 mm. If your condo door has a 38 mm crossbore and you are considering Veno Pro or Veno Plus, contact Lockin Support with the model, measurements, and photos before ordering. Do not enlarge the hole based on an assumption.

Assess light and camera visibility as separate doorway requirements after the physical dimensions are recorded. A shaded corridor may offer little solar assistance even where the hardware fits, and an outer door may obstruct a video model or its movement. Compare the actual entrance with the exact product’s instructions rather than transferring another model’s camera or charging arrangement. Retain a rechargeable-battery plan for a solar candidate, and keep a blocked view or unclear compatibility visible in the purchase decision.

4. Confirm the building’s privacy and camera rules

Resolve permission for the proposed camera view before choosing a video model for a shared hallway. Ask the responsible manager what the installation may cover and how residents, visitors and retained recordings are to be handled under the applicable building arrangements. Decide who will have access to the footage and how ownership will be transferred when the unit changes hands. If that use is not permitted, evaluate a non-video candidate through the same door and permission checks instead of treating a camera feature as an automatic benefit.

Lockin lists Veno Pro with a 2K/180° camera, person/package/vehicle detection, and 32 GB of local video storage. Veno Plus is listed with a 2K/180° camera, person detection, and 8 GB of local storage. Those are model-specific capabilities, not a promise that every Veno lock records video. Lockin also states that biometric data for the Video Veno series is stored locally on the device; connected features such as remote access, alerts, account functions, and integrations still use network services.

5. Preserve required building access and plan everyday entry

Preserve the building’s required access procedure while assigning ordinary household entry. Confirm whether management or an authorized service needs a retained key or another approved route, then choose supported methods for the residents and their backups. Record who owns the Lockin account, who can administer access and how visitors’ permissions will end. These are separate decisions: a useful household code must not silently replace a building requirement, and someone needing entry does not automatically need the administrator password.

6. Make a power and connectivity plan for the condo location

Choose the model around the doorway, not only the feature list. Veno and Veno Go are rated for up to seven months per charge in Lockin’s current product information; Veno Pro and Veno Plus are rated for up to three months. Actual runtime varies with use, connectivity, temperature, camera activity, and settings.

Assign maintenance and connection responsibilities for the actual condo location before ordering. Decide who checks the battery, where charging equipment is kept and how the documented key or emergency-power procedure will remain reachable. For a solar candidate, examine the light at the installed panel position and retain the ordinary charging routine. If the building manages the network, confirm the exact-model setup conditions with the responsible team; a feature list cannot establish that the required connection will be available at the unit door.

7. Use a simple order/no-order gate

Place the order only after the approval, hardware fit, required building access and household maintenance plan have specific answers. Keep the measurements and photographs with the selected model and ask support to resolve any remaining product-fit question before purchasing or changing the door. Use the matching guide for the final check. This is a purchase workflow, not a determination of legal or building compliance; retain the responsible building team’s decisions alongside the product documentation.

Can I order Veno Pro or Veno Plus for a 38 mm crossbore?

Do not assume it. Current Lockin sources agree on 54 mm for the product pages but differ in some linked guide illustrations. Ask support to confirm the exact kit using your model, measurements, and photos before ordering or drilling.

Updated October 15, 2026